Location
Alarm
Description
Code
Code
00
0085 A notice of stat
00
0246 For R&D
00
0247 For R&D
04
0001 Cassette 1 Lifter error
7
Error•Jam•Alarm > Alarm Code > Alarm Code
Details
-
-
-
Cause: Error in Lift Motor or Lifter Sensor
Measures:
1. While Cassette 1 is removed, turn ON the power
and then insert Cassette 1.
When there is operation sound of the motor
1-1. Check the harness/connector between the DC
Controller and the Cassette 1 Lifter Sensor
2-1. Check if the Cassette 1 Lifter Sensor is installed.
3-1. Extend the Sensor Flag of the Cassette 1 Lifter
Sensor by approx. 1.5 mm with Plastic Film, etc.
4-1. Check the condition of the gear at the host
machine side (to see if there is missing or swing with
the gear)
5-1. Replace the Cassette 1 Lifter Sensor
6-1. Replace the DC Controller PCB
When there is no operation sound of the motor
1-2. Check the harness/connector between the DC
Controller and the Cassette 1 Lifter Motor
2-2. Check conduction of the fuse of the DC Controller
3-2. Check the condition of the gear at the host
machine side (to see if there is something missing or
swing with the gear)
4-2. Check the Cassette 1 Lifter Motor
5-2. Replace the DC Controller
7
Error•Jam•Alarm > Alarm Code > Alarm Code
Location
Alarm
Description
Code
Code
04
0002 Cassette 2 Lifter error
Details
Cause: Error in Lift Motor or Lifter Sensor
Measures:
1. While Cassette 2 is removed, turn ON the power
and then insert Cassette 2.
When there is operation sound of the motor
1-1. Check the harness/connector between the DC
Controller and the Cassette 2 Lifter Sensor
2-1. Check if the Cassette 2 Lifter Sensor is installed.
3-1. Extend the Sensor Flag of the Cassette 2 Lifter
Sensor by approx. 1.5 mm with Plastic Film, etc.
4-1. Check the condition of the gear at the host
machine side (to see if there is missing or swing with
the gear)
5-1. Replace the Cassette 2 Lifter Sensor
6-1. Replace the DC Controller PCB
When there is no operation sound of the motor
1-2. Check the harness/connector between the DC
Controller and the Cassette 2 Lifter Motor
2-2. Check conduction of the fuse of the DC Controller
3-2. Check the condition of the gear at the host
machine side (to see if there is something missing or
swing with the gear)
4-2. Check the Cassette 2 Lifter Motor
5-2. Replace the DC Controller