Technical Explanation > MEAP > Maintenance > Collection of MEAP Console Logs
3) Press [RMT-CNSL].
4) Press either 1 (activate remote console function) on control panel (the numerical value
input in the field is displayed), and press [OK].
5) Check to see that it is reflected in setting field, and restart the device.
2
Technical Explanation > MEAP > Maintenance > Collection of MEAP Console Logs
PC setting procedure (when Tera Term is used)
1) Install the terminal software on the PC.
2) Start the terminal software, make the following settings, and then click the [OK].
F-2-307
3) The connection window will open. Select [Terminal] from the [Setup] menu.
F-2-308
F-2-309
Connection
: Select [TCP/IP] (Default)
Host
: Device Host Name or IP Address
Service
: Select "Telnet"
TCP port#
: Enter 19001
2-184
F-2-310
F-2-311
2-184