■ USER
COPIER> OPTION> USER
COPY-LIM
Setting of upper limit for copy
Lv.1 Details
To set the upper limit value for copy.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
1 to 9999
Default value
999
SLEEP
ON/OFF of auto sleep function
Lv.1 Details
To set ON/OFF of auto sleep function.
Use case
Upon user's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
1
Related UI menu
Preferences> Timer/Energy Settings> Auto Sleep Time
Supplement/memo
The time to shift to the sleep mode can be set in Settings/
Registration> Preferences> Timer/Energy Settings> Auto Sleep
Time.
COUNTER1
Display of software counter 1
Lv.1 Details
To display counter type for software counter 1 on the Counter Check
screen.
Use case
Upon user/dealer's request
Adj/set/operate method N/A (Display only)
Caution
Display only. No change is available.
Display/adj/set range
0 to 999
0: Not registered
Default value
Refer to the specification of counter display because it differs
according to the model or the location.
COUNTER2
Setting of software counter 2
Lv.1 Details
To set counter type for software counter 2 on the Counter Check
screen.
Use case
Upon user/dealer's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 999
0: Not registered
Default value
Refer to the specification of counter display because it differs
according to the model or the location.
8
Service Mode > COPIER > OPTION > USER
8
Service Mode > COPIER > OPTION > USER
COPIER> OPTION> USER
COUNTER3
Setting of software counter 3
Lv.1 Details
To set counter type for software counter 3 on the Counter Check
screen.
Use case
Upon user/dealer's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 999
0: Not registered
Default value
Refer to the specification of counter display because it differs
according to the model or the location.
COUNTER4
Setting of software counter 4
Lv.1 Details
To set counter type for software counter 4 on the Counter Check
screen.
Use case
Upon user/dealer's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 999
0: Not registered
Default value
Refer to the specification of counter display because it differs
according to the model or the location.
COUNTER5
Setting of software counter 5
Lv.1 Details
To set counter type for software counter 5 on the Counter Check
screen.
Use case
Upon user/dealer's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 999
0: Not registered
Default value
0
COUNTER6
Setting of software counter 6
Lv.1 Details
To set counter type for software counter 6 on the Counter Check
screen.
Use case
Upon user/dealer's request
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 999
0: Not registered
Default value
0
8-163