Canon imageRUNNER ADVANCE C350 series Service Manual page 882

Table of Contents

Advertisement

■ CLEAR
COPIER> FUNCTION> CLEAR
ERR
Clear of error code
Lv.1 Details
To clear error codes (E000, E001, E002, E003, E717, E719).
Use case
At error occurrence
Adj/set/operate method 1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
DC-CON
RAM clear of DC Controller PCB
Lv.1 Details
To clear the RAM data of the DC Controller PCB.
Use case
When clearing the RAM data of the DC Controller PCB
Adj/set/operate method 1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
- Output the service mode setting values by P-PRINT before
execution. After execution, enter necessary setting values.
- The RAM data is cleared After the main power switch is turned
OFF/ON.
Related service mode
COPIER> FUNCTION> MISC-P> P-PRINT
R-CON
Clear of Reader-related RAM data
Lv.1 Details
To clear the Reader-related RAM data of the Main Controller PCB.
Use case
When clearing the Reader-related RAM data
Adj/set/operate method 1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
- Output the service mode setting values by P-PRINT before
execution. After execution, enter necessary setting value.
- The RAM data is cleared by pressing OK key.
- Data is stored in the Main Controller PCB.
Related service mode
COPIER> FUNCTION> MISC-P> P-PRINT
JAM-HIST
Clear of jam history
Lv.1 Details
To clear the jam history.
Use case
When clearing the jam history
Adj/set/operate method Select the item, and then press OK key.
ERR-HIST
Clear of error code history
Lv.1 Details
To clear the error code history.
Use case
When clearing the error code history
Adj/set/operate method Select the item, and then press OK key.
PWD-CLR
Clear of system administrator password
Lv.1 Details
To clear the password of the system administrator set in Settings/
Registration.
Use case
When clearing the password of the system administrator
Adj/set/operate method 1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
8
Service Mode > COPIER > FUNCTION > CLEAR
8
Service Mode > COPIER > FUNCTION > CLEAR
COPIER> FUNCTION> CLEAR
ADRS-BK
Clear of address book
Lv.1 Details
To clear the address book data.
Use case
When clearing the address book data
Adj/set/operate method 1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
The address book data is cleared after the main power switch is
turned OFF/ON.
CNT-MCON
Clear of Main Controller service counter
Lv.1 Details
To clear the service counter counted by the Main Controller PCB.
Use case
When clearing the service counter counted by the Main Controller
PCB
Adj/set/operate method Select the item, and then press OK key.
Related service mode
COPIER> COUNTER
Supplement/memo
See COUNTER for the target counter.
CNT-DCON
Clear of DC Controller service counter
Lv.1 Details
To clear the service counter counted by the DC Controller PCB.
Use case
When clearing the service counter counted by the DC Controller
PCB
Adj/set/operate method Select the item, and then press OK key.
OPTION
Clear of service mode setting VL(OPTION)
Lv.1 Details
To return the value specified in service mode (COPIER> OPTION) to
the default value (value at the time of RAM clear).
Use case
When clearing setting value of OPTION
Adj/set/operate method Select the item, and then press OK key.
Caution
- Before execution of this item, be sure to output the service mode
setting values by P-PRINT. After execution, enter necessary setting
values.
- This item is executed for the data on the Main Controller PCB, DC
Controller PCB and Reader Controller PCB.
Related service mode
COPIER> FUNCTION> MISC-P> P-PRINT
MMI
Clear of Settings/Registration set VL
Lv.1 Details
To clear the Settings/Registration setting values .
- Preferences (excluding Paper Type Management Settings)
- Adjustment/Maintenance
- Function Settings (excluding Printer Settings)
- Management Settings (excluding Device Management)
Use case
When clearing various setting values related to display on the
Control Panel menu
Adj/set/operate method 1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
The setting value is cleared after the main power switch is turned
OFF/ON.
8-112
8-112

Hide quick links: