2
Technical Explanation > Fixing System > Overview > Specifications
Fixing System
Overview
■ Features
This machine uses the on-demand fixing method.
Fixing Delivery Upper Guide
Separation Guide
Fixing Film
Fixing Heater
2
Technical Explanation > Fixing System > Overview > Specifications
Fixing Delivery
Detection Flag
Delivery Sensor
(PS12)
Pressure Roller
Fixing Inlet Guide
F-2-114
■ Specifications
Item
Fixing method
On-demand fixing
Fixing speed
iR-ADV
35-ppm
C350
machine
iR-ADV
25-ppm
C250
machine
Fixing Heater
Ceramic Heater
Control temperature
iR-ADV
plain paper 1 Full Color: 200 deg C
C350
plain paper 2 Full Color: 210 deg C
iR-ADV
plain paper 1 Full Color: 175 deg C
C250
plain paper 2 Full Color: 185 deg C
Temperature Control
Main Thermistor
Edge temperature
Down sequence
rising control
Fixing Arch Control
Arch Sensor
Protection function
Main Thermistor
(Rated operational temperature: 265 deg C)
Sub Thermistor
(Rated operational temperature: 290 deg C)
Thermoswitch
(Rated operational temperature: 240 deg C)
* If the temperature is under 50 deg C at the start of startup or the environment temperature
is 23 deg C
Varies depending on the temperature at the start of startup and environment temperature
+10 deg C if the paper width is A4R or larger
2-85
Function/method
1/1 speed
200 mm/sec
2/3 speed
135 mm/sec
1/2 speed
100 mm/sec
1/1 speed
-
2/3 speed
135 mm/sec
1/2 speed
100 mm/sec
*
*
Black: 195 deg C
*
Black: 205 deg C
*
*
Black: 170 deg C
*
*
*
Black: 180 deg C
2-85