COPIER> DISPLAY> ANALOG
TEMP2
Display of inside temperature
Lv.1 Details
To display the estimated temperature inside the machine that is
calculated from the outside temperature and elapsed time.
Use case
When checking the estimated temperature inside the machine
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 100
Unit
1 deg C
Appropriate target value Room temperature - Room temperature+15 deg C
Related service mode
COPIER> DISPLAY> ANALOG> TEMP
FIX-E3
Dspl of Fixing Sub Heater rear edge temp
Lv.1 Details
To display the rear edge temperature of the Fixing Sub Heater
detected by the Sub Thermistor 2.
Use case
When checking the edge temperature of the Fixing Sub Heater
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 300
Unit
1 deg C
8
Service Mode > COPIER > DISPLAY > HV-STS
T-8-6
8
Service Mode > COPIER > DISPLAY > HV-STS
■ HV-STS
COPIER> DISPLAY> HV-STS
1ATVC-Y
Dspl of primary transfer current (Y)
Lv.2 Details
To display the decuple value of the current flown to the Primary
Transfer Roller (Y) by the primary transfer ATVC control.
When the two values are out of the target value range (50 to 700),
clear the log information for the appropriate control (COPIER>
FUNCTION> CLEAR> 1TR-CLR).
If the two values are both small, the Primary Transfer Roller may
have reached the end of life.
Use case
When estimating the life of Primary Transfer Roller based on the
displayed value
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 900
Unit
1 uA
Appropriate target value 50 - 700
Related service mode
COPIER> FUNCTION> CLEAR> 1TR-CLR
1ATVC-M
Dspl of primary transfer current (M)
Lv.2 Details
To display the decuple value of the current flown to the Primary
Transfer Roller (M) by the primary transfer ATVC control.
When the two values are out of the target value range (50 to 700),
clear the log information for the appropriate control (COPIER>
FUNCTION> CLEAR> 1TR-CLR).
If the two values are both small, the Primary Transfer Roller may
have reached the end of life.
Use case
When estimating the life of Primary Transfer Roller based on the
displayed value
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 900
Unit
1 uA
Appropriate target value 50 - 700
Related service mode
COPIER> FUNCTION> CLEAR> 1TR-CLR
1ATVC-C
Dspl of primary transfer current (C)
Lv.2 Details
To display the decuple value of the current flown to the Primary
Transfer Roller (C) by the primary transfer ATVC control.
When the two values are out of the target value range (50 to 700),
clear the log information for the appropriate control (COPIER>
FUNCTION> CLEAR> 1TR-CLR).
If the two values are both small, the Primary Transfer Roller may
have reached the end of life.
Use case
When estimating the life of Primary Transfer Roller based on the
displayed value
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 900
Unit
1 uA
Appropriate target value 50 - 700
Related service mode
COPIER> FUNCTION> CLEAR> 1TR-CLR
8-33