Before you begin
Enable echo cancellation as described in
If configuring from the endpoint, you must first enable advanced configuration, as described in
Maintaining the XT Endpoint Locally from the Endpoint
Procedure
1. Access the echo canceller settings as follows:
2. Set the fields as required.
Administrator Guide for Scopia XT5000 Endpoint with Embedded
Server for IP Office Version 3.2
• From the endpoint's main menu, select Configure > Advanced > I/O connections >
Echo Canceller.
• From the XT Endpoint web interface, select Administrator settings > I/O
connections > Echo Canceller.
Figure 38: Configuring the Echo Canceller
Table 23: Configuring echo canceller related settings
Field Name
AGC
Enables/disables Automatic Gain Control (AGC), which is used to
adjust the volume. The AGC reduces the volume if the audio is strong
and raises when it is weak.
Noise reduction
Enables/disables reduction of ambient noise in a conference room
(e.g.: coughing, paper rustling, etc.).