19–16
2.
REMOVE GENERATOR BRUSH HOLDER ASSY
(a)
Remove the nut and terminal insulator.
(b)
Remove the bolt, 3 nuts, plate terminal and end cover.
(c)
Remove the brush cover.
(d)
Remove the 2 screws and brush holder.
3.
REMOVE GENERATOR REGULATOR ASSY
(a)
Remove the 3 screws and voltage regulator.
4.
REMOVE GENERATOR HOLDER W/RECTIFIER
(a)
Remove the 4 screws and rectifier holder.
Wooden block
6.
REMOVE GENERATOR ROTOR ASSY
(a)
Remove the alternator washer from the rotor.
(b)
Remove the rotor from drive end frame.
NOTICE:
Do not drop the rotor.
Ohmmeter
F
2002 CAMRY REPAIR MANUAL (RM881U)
STARTING & CHARGING
–
5.
REMOVE ALTERNATOR RECTIFIRE END FRAME
(a)
Remove the rubber insulator.
(b)
Remove the seal plate.
(c)
Remove the 4 nuts.
(d)
Using bearing puller set, remove the rectifier end frame.
A66906
7.
INSPECT GENERATOR REGULATOR ASSY
(a)
Using an ohmmeter, check the continuity between termi-
nals F and B.
Standard:
When the positive and negative poles between termi-
nals F and B are exchanged, there is continuity in one
B
way but no continuity in another way.
If the continuity is not as specified, replace the voltage regula-
A59143
tor.
GENERATOR ASSY (2AZ–FE)
Author :
Date :
1888