Toyota 2002 Camry Service Manual page 254

Hide thumbs Also See for 2002 Camry:
Table of Contents

Advertisement

Air Inlet Port
Vacuum
Continuity
No Continuity
F
E
F
E
2002 CAMRY REPAIR MANUAL (RM881U)
EMISSION CONTROL
Purge Port
If operation is not as specified, replace the charcoal canister.
EVAP
Port
A59506
(c)
Ohmmeter
If there is no continuity, replace the VSV.
A59507
Ohmmeter
If there is continuity, replace the VSV.
A59508
Air
A59509
If operation is not as specified, replace the VSV.
Air
A59510
EMISSION CONTROL SYSTEM (1MZ–FE)
(5)
While holding the air inlet port closed, apply vacuum
(3.43 kPa, 25.7 mmHg, 1.01 in.Hg) to the EVAP port
and check that air flows into the purge port.
(6)
Remove the hose and cap from vent port.
Inspect VSV for pressure switching valve
(1)
Using an ohmmeter, check that there is continuity
between the terminals.
Resistance:
37 – 44 Ω at 20_C (68_F)
51 – 62 Ω at 120_C (248_F)
(2)
Using an ohmmeter, check that there is no continu-
ity between each terminal and the body.
(3)
Check that air does not flow from ports E to F.
(4)
Apply battery positive voltage across the terminals.
(5)
Check that air flows from ports E to F.
Author :
12–17
Date :
1510