Hard disk drives / solid state drives
7.3.3.4
Concluding steps
Perform the following procedures to complete the task:
Ê Close the front cage as described in section
page
68.
Ê Close the server cover as described in section
on page
72.
7.3.4
Replacing a 3.5-inch HDD module
Upgrade and Repair Units (URU)
Average task duration: 10 minutes
V
CAUTION!
Only remove an HDD module during operation if the drive is not
●
currently being accessed. Observe the indicators for the
corresponding HDD modules, see "PRIMERGY TX120 S3 Server
Operating Manual".
Under no circumstances should you remove an HDD module while
●
the system is in operation if you are not sure that the drive is operated
by a RAID controller and belongs to a disk array that is operating in
RAID level 1, 1E, 10, 5, 50, 6 or 60.
An HDD module can only be replaced during operation in conjunction
with a corresponding RAID configuration.
All HDD modules (drives) must be uniquely identified so that they can
●
be reinstalled in their original mounting locations later. If this is not
done, existing data can be lost.
7.3.4.1
Required tools
Preliminary and concluding steps: tool-less
●
Replacing a 3.5-inch HDD module: tool-less
●
140
Upgrade and Maintenance Manual
"Closing the front cage" on
"Mounting the server cover"
TX120 S3