Minimum startup configuration

Field Replaceable Units (FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
System board
CPU with CPU heat sink
1 memory module
Front panel module
Power supply unit
Table 9: Minimum startup configuration - components
Cable
Front panel cable
Power cable
Table 10: Minimum startup configuration - cables
Ê Shut down the server as described in section
page
58.
Ê Remove the AC power cord from the cable tie and disconnect it from the
system as described in section
Ê Take the system down to its minimum startup configuration.
TX120 S3
Notes and reference
no TPM, UFM or expansion cards installed
no fan (disconnect fan cable)
installed in DIMM slot 1A, see section
"Memory sequence" on page 234
Notes and reference
see section
on page 373
see section
page 380
"Disconnecting power cords" on page
Upgrade and Maintenance Manual
"Replacing the front panel cable"
"Replacing the power cable" on
"Shutting down the server" on
Appendix
59.