Basic hardware procedures
4.1.3.1
Local diagnostic indicators on the front
Figure 6: Local diagnostic indicators on front panel
Ê Check the local diagnosis indicator lamp (1) - (6) at the front of the server:
Indicator
HDD error
1
indicator
PSU error
2
indicator
Temperature
3
error indicator
CPU error
4
indicator
Memory error
5
indicator
Fan error
6
indicator
I
In addition to local diagnostic indicators, CSS or Global Error LEDs
indicate, if the defective component is a customer or field replaceable
unit (see section
54
Status
yellow on
orange on
orange on
orange on
orange on
orange on
"Determining the error class" on page
Upgrade and Maintenance Manual
Description
HDD / SSD, SAS / SATA backplane or
RAID controller failure detected
PSU module failure detected
Operating temperature levels above
permitted limits
CPU pre-failure event detected
Memory module failure detected
Fan pre-failure or failure event
detected
51).
TX120 S3