7.2.3
Removing 2.5-inch HDD / SSD modules
Customer Replaceable Units (CRU)
Average task duration: 5 minutes
7.2.3.1
Required tools
Preliminary and concluding steps: tool-less
●
Removing a 2.5-inch HDD / SSD module: tool-less
●
7.2.3.2
Preliminary steps
Before removing a 2.5-inch HDD / SSD module, perform the following steps:
Ê Ensure that the HDD / SSD module to be removed is not combined into a
RAID array. If the drive is part of a RAID array, you first need to delete the
array using ServerView RAID Manager.
V
CAUTION!
All data on all HDDs / SSDs in the array will be lost! Be sure to back
up your data before deleting a RAID array.
I
For further information, please refer to the "ServerView Suite RAID
Management" user guide, available online at
http://manuals.ts.fujitsu.com
http://jp.fujitsu.com/platform/server/primergy/manual/
market) or from the ServerView Suite DVD 2 supplied with your
PRIMERGY server.
Ê Remove the hard disk drive cover as described in section
hard disk drive cover" on page
TX120 S3
(EMEA market) or
65.
Upgrade and Maintenance Manual
Hard disk drives / solid state drives
(Japanese
"Removing the
125