Detail Signal Frequency Adjustment - Sony HDCAM HDW-F900R Maintenance Manual

Down converter board
Hide thumbs Also See for HDCAM HDW-F900R:
Table of Contents

Advertisement

9-19. Detail Signal Frequency
Adjustment
Note
Perform this adjustment as needed by the customer.
Preparation
. Complete the setting as shown below by using the setup
menu.
MENU : PAINT
PAGE : 08*DETAIL1
ITEM : DETAIL → ON
. OUTPUT/DCC switch (inside panel) → CAM/ON
. Shoot the gray scale chart to fill the entire screen of the
under-scanned picture frame.
Equipment :
HD digital waveform monitor
Measurement point : HD SDI connector (rear panel)
1lens iris
Adjustment point :
A = 700 ± 14 mV.
Specifications :
. Select a horizontal scanning line in the bottom of the
white area in the center of the waveform monitor using
the LINE SELECT function.
HDW-F900R/V1 (E)
Adjustment Procedure
Equipment :
Measurement point : HD SDI connector (rear panel)
1. Complete the adjustment as shown below by using the
setup menu.
MENU :
PAGE :
ITEM :
Specifications : Adjust the edge width of the B portion
Note
A
Upon completion of this adjustment, be sure to perform the
following two adjustments : "9-20. H/V Ratio Adjustment"
and "9-21. Detail Signal Level Adjustment".
HD digital waveform monitor
PAINT
08*DETAIL1
DETAIL FREQ.
for the customer's preference.
B
9-21

Hide quick links: