Sony HDCAM HDW-F900R Maintenance Manual page 115

Down converter board
Hide thumbs Also See for HDCAM HDW-F900R:
Table of Contents

Advertisement

E-x71
Contents :
Abnormality is detected in the system control initialization command.
Detecting conditions : The initialization command is not completed within the specified time at the event
of power-on with a cassette being inserted.
. Signal path between the FP-152 board and the SS-92G board is defective.
Suspected cause :
E-x80
Contents :
Communication error between SS and EQ
Detecting conditions : Communication cannot be established between the SS-92G board and the EQ-88G
board.
Suspected cause :
The EQ board is defective.
E-x81
Contents :
EQ switching pulse error
Detecting conditions : None of the switching pulses in the EQ-88G board changes from "H".
Suspected cause :
Connection among the MDC-13G board, MDR-14G board, and EQ-88G board is
faulty.
E-x82
Contents :
Communication error between SS and AT
Detecting conditions : Communication failure with AT exceeds three seconds, or the checksum of the
data sent from AT does not match for three seconds or more.
. Connection of the connectors on the SS-92G board, AT-172 board, and DCP-43
Suspected cause :
board is faulty.
. The SS-92G board or the AT-172 board is defective.
E-x83
Contents :
SS-92G/IC13 program load error
Detecting conditions : Loading of a program to the SS-92G board IC13 is not complete.
Suspected cause :
The SS-92G board IC13 is defective.
E-x86
Contents :
FORMAT difference error
Detecting conditions : FORMAT of the camera and FORMAT of the VTR are different.
Suspected cause :
Connection between AT and SS is faulty.
E-x88
Contents :
EEPROM writing error
Detecting conditions : Writing error has occurred in the servo EEPROM.
. The MDC-13G board IC403 is defective.
Suspected cause :
. Signal path between the SS-92G board and the MDC-13G board is faulty.
HDW-F900R/V1 (E)
3-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents