Adjustment Procedure
1. Alignment tape playback
Play back the alignment tape HR2-1A (from 15 :
00 to 30 : 00).
2. CUE Head azimuth adjustment
(1) Rotate the azimuth adjustment screw either in
clockwise or counter-clockwise direction
until the maximum output waveform is
obtained.
(2) Repeat changing the mode from the EJECT
state to the PLAY state a few times and
confirm that the output level remains un-
changed and the same as that in step (1).
(3) Repeat changing the mode from REV x 3 to
PLAY a few times and confirm that the
output level remains unchanged and the same
as that in step (1).
How to enter the REV x x x x x 3 mode
After pressing the PLAY button, press the
REW button. (Both the PLAY and REW
buttons on the keyboard turn on.)
3. CUE/TC head tape-to-head contact
check
(Refer to Section 8-2-7.)
4. CUE/TC head height check
(Refer to Section 8-2-5.)
5. CUE/TC head position adjustment
(Refer to Section 8-2-8.)
8-40
CUE/TC head assembly
Azimuth adjustment screw
Maximum the amplitude.