6-2. Filter Disk Unit Replacement

n
Replace the filter disk unit in the place such as clean room
that is free from dust.
Removal
1. Remove the outside panel assembly.
(Refer to Section 1-4.)
2. Open the inside panel assembly.
(Refer to Section 1-5.)
3. Remove the CCD unit. (Refer to 6-1-1.)
4. Remove the two screws and disconnect the harness
from the connector (CN3) on the DR-614 board and
take the filter disk unit out gently.
Installation
1. Install the new filter disk unit by reversing step 4 of
removal.
n
When installing the filter disk unit, be careful not
touch the surface of the filter disk unit with hand.
2. Install the CCD unit. (Refer to Section 6-1-1.)
Adjustment after Replacement
Adjustment after Replace of the Filter Disk Unit
(Refer to Section 9-28.)
HDW-F900R/V1 (E)
Filter disk unit
K3 x 6
CCD unit
CN3
DR-614
board
6-5