6
6
6
6 C005 : FUNCTION CAM POS
6
Indicates the detecting position of the function gear.
1. Select "C005: FUNCTION CAM POS" and press the rotary
encoder.
2. Insert a working tape (blank tape: BCT-40HD that is commercial-
ly available) and check to see that the arrow mark (→) moves.
3. Check to see that the arrow mark (→) moves when the tape
EJECT button is pressed.
m
If the arrow mark (→) does not move even when the tape is
inserted or ejected, check the followings.
. Function cam sensor (PH301 to PH304/MDC-13G board)
. Cam position detector circuit (Q301 and others/MDC-13G
board, IC1 and others/SS-92G board)
. Signal path between the MDC-13G board and the SS-92G board
If the function cam does not operate correctly, the SLACK error
occurs. Take an appropriate measure in accordance with the corre-
sponding error code referring to Section "3. Error Diagnostics".
n
The display on monitor changes in accordance with the
status of the function cam sensor as shown in the Function
Cam Code Transition Table.
The status of each sensor can be checked by either one of
the following two methods.
1. Observe the check-land (CL301 to CL304/MDC-13G
board) with an oscilloscope. The SS-92G board must
have been removed earlier to connect an oscilloscope
to the check-land. As the function cam can be moved
of its position by hand, the sensor status also changes.
Move the function cam by hand as follows and check
that the sensor status changes accordingly as shown in
the table.
. While pushing the manual eject gear with a flat-head
screwdriver tip, rotate the manual eject gear in the
clockwise direction (unloading direction) or counter-
clockwise direction (loading direction). (Refer to
Section 1-11.)
n
If the front lid has been opened, never rotate the gear
in the clockwise direction.
2. Connect the SS-92G board connector (CN201) and the
MDC-13G board connector (CN201) with the use of
the EX-764 board and the two flexible card wires (45
pins). Check the function cam sensor status with an
oscilloscope referring to the function cam code
transition table.
In this case, the function cam is controlled of its
position automatically by the SS-92G board. There-
fore, check that the function cam sensor status matches
with the monitor display as shown in the Function
Cam Code Transition table.
HDW-F900R/V1 (E)
SERVO CHECK MENU
C005:FUNCTION CAM POS
1.B0
2.EJECT
3.B1
4.STBY
5.B2
6.LOAD1
7.LOAD2
8.LOAD
Function Cam Code Transition Table
Detecting
Sensor status (MDC-13G board)
position
Monitor
CL304
CL303
display
(CN201-39) (CN201-40) (CN201-41) (CN201-42)
B0
H
L
EJECT
H
L
B1
H
L
STBY
H
L
B2
H
H
LOAD1
H
H
LOAD2
H
H
LOAD
H
H
LIMIT
L
H
B3
L
H
STOP
L
H
B4
L
H
RUN
L
L
B5
L
L
CL
L
L
B6
L
L
9.LIMIT
10.B3
11.STOP
12.B4
13.RUN
14.B5
15.CL
16.B6
CL302
CL301
L
L
L
H
H
H
H
L
H
L
H
H
L
H
L
L
L
L
L
H
H
H
H
L
H
L
H
H
L
H
L
L
MDC-13G board (A side)
11-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents