3-4-2. Detail Level Adjustment
Equipment: Waveform monitor (R, G, B)
Test Point: SDI 1 and SDI 2 connectors
Object:
Grayscale chart
Preparations
. Setting for MSU-900
DETAIL OFF button→ ON (dark)
KNEE OFF button→ OFF (lit)
. Shoot the grayscale chart so that the chart frame is
aligned with the underscanned monitor frame.
. Iris of the lens: A = 600 ?20 mV
Adjustment Procedure
MSU menu operation:
. PAINT button → ON (lit)
. Touch panel operation
(Page 1/4) → [Detail] → [Detail|1]
Adjustment item: Level
Specifi cation:
Adjust the detail level to be added to
each step of the grayscale to the
desired level.
HDC-P1
A
3-17 (E)