24.6.3
Output Waveform during LCD Controller Operation (1/4 Duty)
In 1/4 duty mode, all of COM0, COM1, COM2, and COM3 are used for display.
1/3 Bias, 1/4 Duty Output Waveform Example
Those liquid crystal elements are turned "ON" for display which has the maximum potential
difference between the common and segment outputs.
Figure 24.6-4 shows the output waveform when the contents of display RAM are those shown in
Table 24.6-3.
Table 24.6-3 Sample Contents of Display RAM
Segment
SEG n
SEG n+1
Contents of Display RAM
COM3
COM2
0
1
0
1
CHAPTER 24 LCD CONTROLLER
COM1
0
0
COM0
0
1
459