Programming Guide | VLT® HVAC Drive FC 102
Option
Name
[74]
Logic rule 4
[75]
Logic rule 5
[76]
Logic rule 6
[77]
Logic rule 7
[78]
Logic rule 8
[79]
Logic rule 9
[80]
SL digital output A
[81]
SL digital output B
[82]
SL digital output C
[83]
SL digital output D
[84]
SL digital output E
[85]
SL digital output F
[90]
kWh counter pulse
[150]
CBM warning
[151]
ATEX ETR cur. alarm
[152]
ATEX ETR freq. alarm
[153]
ATEX ETR cur. warning
622
| © 2024.10
Description
See parameter group 13-4* Logic Rules. If logic rule 4 in SLC is true,
the output goes high. Otherwise, it is low.
See parameter group 13-4* Logic Rules. If logic rule 5 in SLC is true,
the output goes high. Otherwise, it is low.
See parameter group 13-4* Logic Rules. If logic rule 6 in SLC is true,
the output goes high. Otherwise, it is low.
See parameter group 13-4* Logic Rules. If logic rule 7 in SLC is true,
the output goes high. Otherwise, it is low.
See parameter group 13-4* Logic Rules. If logic rule 8 in SLC is true,
the output goes high. Otherwise, it is low.
See parameter group 13-4* Logic Rules. If logic rule 9 in SLC is true,
the output goes high. Otherwise, it is low.
See parameter 13-52 SL Controller Action. Output A is low on
smart logic action [32] Set digital out A low. Output A is high on
smart logic action [38] Set digital out A high.
See parameter 13-52 SL Controller Action. Output B is low on
smart logic action [33] Set digital out B low. Output B is high on
smart logic action [39] Set digital out B high.
See parameter 13-52 SL Controller Action. Output C is low on
smart logic action [34] Set digital out C low. Output C is high on
smart logic action [40] Set digital out C high.
See parameter 13-52 SL Controller Action. Output D is low on
smart logic action [35] Set digital out D low. Output D is high on
smart logic action [41] Set digital out D high.
See parameter 13-52 SL Controller Action. Output E is low on
smart logic action [36] Set digital out E low. Output E is high on
smart logic action [42] Set digital out E high.
See parameter 13-52 SL Controller Action. Output F is low on
smart logic action [37] Set digital out F low. Output F is high on
smart logic action [43] Set digital out F high.
Selectable if parameter 1-90 Motor Thermal Protection is set
to [20] ATEX ETR or [21] Advanced ETR. If alarm 164, ATEX ETR
cur.lim.alarm is active, the output is 1.
Selectable if parameter 1-90 Motor Thermal Protection is set
to [20] ATEX ETR or [21] Advanced ETR. If alarm 166, ATEX ETR
freq.lim.alarm is active, the output is 1.
Selectable if parameter 1-90 Motor Thermal Protection is set
to [20] ATEX ETR or [21] Advanced ETR. If alarm 163, ATEX ETR
cur.lim.warning is active, the output is 1.
Parameter Descriptions
AU430028034214en-001901 / 130R0310