Programming Guide | VLT® HVAC Drive FC 102
8-54 Reversing Select
Default value:
–
Setup:
All setups
Data type:
Uint8
Select the trigger for the reversing function.
Option
Name
[0]
Digital input
[1]
Bus
[2]
Logic AND
[3]
Logic OR
8-55 Set-up Select
Default value:
[3] Logic OR
Setup:
All setups
Data type:
Uint8
Select the trigger for the setup selection.
Option
Name
[0]
Digital input
[1]
Bus
[2]
Logic AND
[3]*
Logic OR
8-56 Preset Reference Select
Default value:
[3] Logic OR
Setup:
All setups
Data type:
Uint8
Select the trigger for the preset reference selection.
© 2024.10
Parameter type:
Conversion index:
Change during operation:
Description
A digital input triggers the reversing function.
A serial communication port or the fieldbus triggers the
reversing function.
The fieldbus/serial communication port and a digital input
trigger the reversing function.
The fieldbus/serial communication port or a digital input triggers
the reversing function.
Parameter type:
Conversion index:
Change during operation:
Description
A digital input triggers the setup selection.
A serial communication port or the fieldbus triggers the setup
selection.
The fieldbus/serial communication port and a digital input
trigger the setup selection.
The fieldbus/serial communication port or a digital input triggers
the setup selection.
Parameter type:
Conversion index:
Change during operation:
AU430028034214en-001901 / 130R0310 |
Parameter Descriptions
Option
–
True
Option
–
True
Option
–
True
237