398
Restart the unit
Red/green flashing
using the reset pin hole
Check LED STATUS
Red/green, solid or flashing
Action
Check the STATUS LED on the Connec-
ted Services Gateway.
Reset the module to factory using the re-
set pin hole for more than 5s, and restart
the controller.
Check the STATUS LED on the Connec-
ted Services Gateway.
© Copyright 2022-2023 ABB. All rights reserved.
Troubleshooting Connected
Services Gateway 3G or WiFi
Check LED STATUS
Not lit
Not lit
Check LED LINK
Not lit or solid
Measure input voltage
Ok
Check connector X2
Ok
Check LED RF
Ok
Check connector X3
Ok
Check antenna,
sim card etc.
Ok
Replace the Connected
Services Gateway
Note
If the LED is:
Proceed with step 3.
If the LED is:
Product manual - OmniCore V400XT
Troubleshoot main
Not ok
computer
Not ok
Repair connection
Not ok
Not ok
Troubleshoot
Not ok
connectivity of 3G/sim
card/WiFi, antenna
Red/green, flashing: proceed with
step 2.
OFF, the unit is faulty, or it does
not have sufficient input voltage,
or the connection of the connector
X2 is not ok. Proceed with step 5.
Red/green, flashing: An internal
error has occurred, proceed with
step 13.
OFF, the unit is faulty, or it does
not have sufficient input voltage,
or the connection of the connector
X2 is not ok. Proceed with step 5.