A
B
C
D
E
Required test equipment
Equipment needed for troubleshooting:
Equipment
Multimeter
Insulating gloves
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
7.3.4 Troubleshooting the additional drive unit
Name
MS (Module Status) LED
LA (Link Activity [0]) LED
RUN (EtherCAT RUN) LED
LA (Link Activity [1]) LED
DC-BUS High Voltage LED
© Copyright 2022-2023 ABB. All rights reserved.
7 Troubleshooting
Description
The status indicator LED can be used to
identify the following status during star-
tup/power on:
•
Red, steady: Default when power is
available.
•
Red, flashing (~1Hz): Power is on, self-
test is ongoing, operating system is
loading.
•
Green, flashing (~1Hz): Application is
loaded and waiting for communication.
•
Green, steady: Drive unit is operation-
al.
If the LED does not turn steady green after
30-60 sec, the status indicator LED can be
used to identify the following issues:
•
No color: Power to the drive unit is
missing.
•
Red, steady: Internal error.
•
Red, flashing (~1Hz): Firmware error
or self-test failure.
•
Green, flashing (~1Hz): Communica-
tion error to another module.
Shows the Link activity of the EtherCAT slave
port 0.
•
Off: No link
•
Yellow flashing: Link and activity.
•
Yellow steady: Link without activity.
Shows the actual state of the device state
machine:
•
Off: Drive unit is in state INIT.
•
Green flashing (slow): Drive unit is in
state PRE-OPERATIONAL.
•
Green single flash: Drive unit is in
state SAFE-OPERATIONAL.
•
Green steady: Drive unit is in state
OPERATIONAL.
•
Green flickering (fast): Drive unit is in
state BOOTSTRAP.
Shows the Link activity of the EtherCAT slave
port 1.
•
Off: No link
•
Yellow flashing: Link and activity.
•
Yellow steady: Link without activity.
•
No color: Voltage between DC+ - DC-
< 60 VDC
•
Yellow: Voltage between DC+ - DC- >
60 VDC
Note
Continues on next page
Continued
377