3 Installation and commissioning
3.7.9 Installing the mains connections cable
Continued
3
4
5
6
7
8
9
150
Action
Connect incoming mains from an external
earth fault protection.
Fit the cable trough the cable gland (A)
and tighten.
Strip the insulation on the mains cable
long enough to reach the incoming mains
switch (B).
Connect protective earth to one of the
two screws.
Route the phase wires through the pipe
up to the incoming mains switch (B).
Connect the wires to the incoming mains
switch (B).
Refit protection on the incoming mains
switch (B).
© Copyright 2022-2023 ABB. All rights reserved.
Note/illustration
Connecting incoming mains and protective
earth to the controller on page
xx2100002287
Note
Use cable lugs in the connection.
Tightening torque: 5 Nm
See circuit diagram.
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A