ABB OmniCore V400XT Product Manual page 132

Table of Contents

Advertisement

3 Installation and commissioning
3.7.5 Installing the power supply optional device
Continued
Spare part
DSQC 609 power supply
DSQC 634 power supply
Harness PSU 24V
Harness PSU
End clamp
Required tools and equipment
Equipment
Standard toolkit
ESD protective wrist band
Required documents
Document
Circuit diagram - OmniCore
V400XT
Installing the optional power supply
Preparations
1
2
3
Continues on next page
132
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
29.
Open the door.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
45.
© Copyright 2022-2023 ABB. All rights reserved.
Article number
Note
3HAC14178-1
DSQC 609
3HAC13398-2
DSQC 634
3HAC082083-001
DSQC 609 and DSQC 634
3HAC082508-001
DSQC 609 and DSQC 634
3HAB7983-1
Article number
Note
-
Content is defined in section
Standard toolkit for controller on
page
-
Article number
Note
3HAC082020-008
Note/Illustration
Opening the door on page
Location of wrist strap button:
xx2300001842
Product manual - OmniCore V400XT
424.
182.
3HAC081697-001 Revision: A

Advertisement

Table of Contents
loading

Table of Contents