5 Repair
5.2.12 Replacing the power supply
Continued
Refitting the DSQC 609 power supply
Refitting the power supply
1
2
3
4
Continues on next page
254
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
29.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
45.
Fit the power supply to the bracket and
fasten it with screw.
Reconnect any connectors disconnected
at removal.
© Copyright 2022-2023 ABB. All rights reserved.
Note/Illustration
Location of wrist strap button:
xx2300001842
Screws: Cross recessed cheese head screw
M4x8 (1 pcs)
Tightening torque: 1.7 Nm±10%.
xx1900001908
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A