3 Installation and commissioning
3.7.4 Installing additional drive units
Continued
3
4
Concluding procedure
1
2
130
Action
Fit the additional drive unit and secure
with the screws.
Connect:
T4.X7 -X12, T4.X15
T4.X17 - A1.X2
T4.X13 - A1.X11
T4.X5 - A1.X4
T4.X3 - A1.X12
T4.X1 - A1.X5
Action
Close the door.
Perform the function tests to verify that
the safety features work properly, see
Function tests on page
171.
© Copyright 2022-2023 ABB. All rights reserved.
Note/Illustration
Screws: Torx pan head screw M4x8 (4 pcs)
Tightening torque: 2 Nm
xx2200001375
Note/Illustration
Closing the door on page
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
183.