ABB OmniCore V400XT Product Manual page 383

Table of Contents

Advertisement

B
C
D
E
F
G
Required test equipment
Equipment needed for troubleshooting:
Equipment
Multimeter
Insulating gloves
Circuit diagram - OmniCore V400XT
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
Name
MODULE STATUS
ECAT STATUS
SPEED
LINK/ACT
SPEED
LINK/ACT
© Copyright 2022-2023 ABB. All rights reserved.
7 Troubleshooting
7.3.5 Troubleshooting the power unit
Description
The Module status LED indicates the follow-
ing:
No color: AC_IN is missing or
24V_TRUNK is not available.
Red, flashing: Performing self test.
Red, steady: An error has occurred
and unit is in error state.
Green, flashing: Unit is waiting for
24V_SYS and internal communication.
Green, steady: Unit is in operational
state. Activating CTRL inputs in this
state will charge DC_OUT.
The EtherCAT Device State LED/RUN LED
displays the actual state of the device state
machine. The run state is as follows:
Off: Power unit is in state INIT.
Green flashing (slow): Power unit is in
state PRE-OPERATIONAL.
Green single flash: Power unit is in
state SAFE-OPERATIONAL.
Green steady: Power unit is in state
OPERATIONAL.
Green flickering (fast): Power unit is
in state BOOTSTRAP.
Shows the network communication speed.
Green steady: Speed is 100 Mbps.
Off: Speed is 10 Mbps.
Shows the Link activity of the EtherCAT slave
port 1.
Off: No link
Yellow flashing: Link and activity.
Yellow steady: Link without activity.
Shows the network communication speed.
Green steady: Speed is 100 Mbps.
Off: Speed is 10 Mbps.
Shows the Link activity of the EtherCAT slave
port 0.
Off: No link
Yellow flashing: Link and activity.
Yellow steady: Link without activity.
Note
3HAC082020-008
Continues on next page
Continued
383

Advertisement

Table of Contents
loading

Table of Contents