For further information refer to regional power supply standards.
Allowed isolation transformer types
The following isolation transformer types are allowed by ABB:
Delta-Wye isolation transformer (△/Y)
xx1700001318
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
characteristics out of standard limits. To some extent, isolation transformers
will filter out harmonics, spikes and surges.
A Primary/input
B Secondary/output
© Copyright 2022-2023 ABB. All rights reserved.
3 Installation and commissioning
3.5.3 Power supply system requirements
Wye-Wye isolation transformer (Y /Y)
xx1700001319
Continued
79