ABB OmniCore V400XT Product Manual page 100

Table of Contents

Advertisement

3 Installation and commissioning
3.5.9 Descriptions for connectors
Continued
A protective stop device needs to be connected to the protective stop input. See
example below.
Customer provided
protec ve stop device
xx2300000993
The protective stop input can be powered from an external power supply:
Customer provided power
xx2300000994
Continues on next page
100
A2.K5.X15
18
16
15
17
8
10
9
7
Customer provided
protec ve stop device
Customer_24V_CH1
Customer_0V_CH1
Customer_24V_CH2
Customer_0V_CH2
© Copyright 2022-2023 ABB. All rights reserved.
24V_CH1_EXT
AS_CH1_P
AS_CH1_N
0V_IO_EXT
24V_CH2_EXT
AS_CH2_P
AS_CH2_N
0V_IO_EXT
A2.K5.X15
18
24V_CH1_EXT
AS_CH1_P
16
AS_CH1_N
15
17
0V_IO_EXT
8
24V_CH2_EXT
AS_CH2_P
10
AS_CH2_N
9
7
0V_IO_EXT
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A

Advertisement

Table of Contents
loading

Table of Contents