Required documents
Document
Circuit diagram - OmniCore
V400XT
Removing the main computer fan
Preparations
1
2
3
4
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
29.
Open the door.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
45.
If necessary, remove the Connected
Services gateway.
© Copyright 2022-2023 ABB. All rights reserved.
5.2.2.3 Replacing the main computer fan
Article number
Note
3HAC082020-008
Note/Illustration
Opening the door on page
Location of wrist strap button:
xx2300001842
Removing the Connected Services gateway
on page
210.
5 Repair
Continued
182.
Continues on next page
197