ABB OmniCore V400XT Product Manual page 250

Table of Contents

Advertisement

5 Repair
5.2.11 Replacing the HVLP power unit (DSQC3072)
Continued
3
4
Concluding procedure
1
2
250
Action
Position the power unit on the lower
guiding pin on the mounting plate, and
then tip the unit upwards against the up-
per guiding pin. Secure the screws.
Reconnect any connectors disconnected
at removal.
Action
Close the door.
Perform the function tests to verify that
the safety features work properly, see
Function tests on page
171.
© Copyright 2022-2023 ABB. All rights reserved.
Note/Illustration
Screws: Torx pan head screw M4x8 (4 pcs)
Tightening torque: 2 Nm
xx2300001492
Note/Illustration
Closing the door on page
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
183.