Line fusing
As baseline there is no integrated fuse or circuit breaker. The option 3008-3 Mains
connector/Fuse includes integrated circuit breaker.
Robot
IRB 460
IRB 660
IRB 760
IRB 2600
IRB 4600
IRB 5710
IRB 5720
IRB 6650
IRB 6660
IRB 6700
IRB 6710
IRB 6720
IRB 6730
IRB 6740
IRB 7600
Residual current
An external earth fault protection (residual current device, RCD) is required. For
detailed information on how to select an external earth fault protection, see
Connecting incoming mains and protective earth to the controller on page
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
Voltage (V)
380 VAC-480 VAC, 3-phase
380 VAC-480 VAC, 3-phase
380 VAC-480 VAC, 3-phase
380 VAC-480 VAC, 3-phase
380 VAC-480 VAC, 3-phase
380 VAC-480 VAC, 3-phase
380 VAC-480 VAC, 3-phase
380 VAC-480 VAC, 3-phase
380 VAC-480 VAC, 3-phase
380 VAC-480 VAC, 3-phase
380 VAC-480 VAC, 3-phase
380 VAC-480 VAC, 3-phase
380 VAC-480 VAC, 3-phase
380 VAC-480 VAC, 3-phase
380 VAC-480 VAC, 3-phase
Note
For details about installations according to UL requirements, see
incoming mains and protective earth to the controller on page
Note
The integrator is responsible to address local electrical requirements.
© Copyright 2022-2023 ABB. All rights reserved.
2 Controller description
2.2 Technical data for OmniCore V400XT controller
Current (A)
3x32 A
3x32 A
3x32 A
3x16 A
3x32 A
3x32 A
3x32 A
3x32 A
3x32 A
3x32 A
3x32 A
3x32 A
3x32 A
3x32 A
3x32 A
Continued
Connecting
83.
83.
Continues on next page
41