5 Repair
5.3.2.1 Replacing the motor connector
Continued
2
3
4
5
Concluding procedure
1
Continues on next page
292
Action
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
45.
Insert the motor connector into the front
panel from inner side of the cabinet and
fasten it with the screws.
Reconnect any connectors disconnected
at removal.
Secure the motor connector cables with
the velcro on the frame of the cabinet.
Tip
Use the same position as from removing
the motor connector.
Action
Close the door.
© Copyright 2022-2023 ABB. All rights reserved.
Note/Illustration
Location of wrist strap button:
xx2300001842
Screws: Torx, countersunk screw M4x10 (4
pcs)
Tightening torque: 2.7 Nm±10%.
xx2100000813
Note/Illustration
Closing the door on page
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
183.