ABB OmniCore V400XT Product Manual page 229

Table of Contents

Advertisement

2
Refitting the safety digital base device
Refitting the safety digital base device
1
2
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
Action
Push the buckle of the digital base
slightly and take out the digital base.
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
29.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
45.
© Copyright 2022-2023 ABB. All rights reserved.
5.2.7 Replacing the safety digital base device
Note/Illustration
xx2200001972
Note/Illustration
Location of wrist strap button:
xx2300001842
Continues on next page
5 Repair
Continued
229