ABB OmniCore V400XT Product Manual page 82

Table of Contents

Advertisement

3 Installation and commissioning
3.5.5 Fitting the connector for incoming mains
Continued
Procedure
Use the following procedure to fit the connectors.
1
2
3
4
82
Action
Cut the cable to desired length.
Connect the wires according to the illus-
tration.
Tighten the screws to secure the cables.
Remove screw and washer on top of
contact and insert the ground cable with
cable lug. Secure with washer and
screws.
© Copyright 2022-2023 ABB. All rights reserved.
Note/illustration
4
2
3
1
xx2100001258
Description
1
L1
2
L2
3
L3
4
Not used
PE1
Protective earth
PE2
Protective earth
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
PE1
4
2
3
1
PE2

Advertisement