5 Repair
5.2.14 Replacing the additional drive unit
Continued
3
Removing the drive unit
1
2
3
Continues on next page
266
Action
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
45.
Action
Pull the cable ties out from the locking
holes.
Tip
Take photos of the cable ties and locking
holes before pulling out, to have as a
reference when refitting the cable ties.
Disconnect all connectors from the unit
to be replaced.
Remove the screws and pull the drive
unit out from the two guiding pins on the
mounting plate.
CAUTION
The cabling is sensitive to mechanical
damage. Handle it with care to avoid
damage to the cabling or the connector,
avoid any kind of tilt or skew.
© Copyright 2022-2023 ABB. All rights reserved.
Note/Illustration
Location of wrist strap button:
xx2300001842
Note/Illustration
Lengthened screwdriver
xx2200001375
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A