Required tools and equipment
Equipment
Standard toolkit
ESD protective wrist band
Required documents
Document
Circuit diagram - OmniCore
V400XT
Application manual - Conveyor
tracking
Removing the conveyor tracking module (option)
Preparations
1
2
3
Removing the conveyor tracking module (option)
1
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
5.2.16 Replacing the conveyor tracking module (CTM)
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
29.
Open the door.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
45.
Action
Disconnect all connectors from the unit
to be replaced.