A protective stop device needs to be connected to the protective stop input. See
example below.
Customer provided
protec ve stop device
xx2300000995
The protective stop input can be powered from an external power supply:
Customer provided power
xx2300000996
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
A2.K5.X14
16
14
13
15
10
12
11
9
Customer provided
protec ve stop device
Customer_24V_CH1
Customer_0V_CH1
Customer_24V_CH2
Customer_0V_CH2
© Copyright 2022-2023 ABB. All rights reserved.
3 Installation and commissioning
3.5.9 Descriptions for connectors
24V_CH1_EXT
GS_CH1_P
GS_CH1_N
0V_IO_EXT
24V_CH2_EXT
GS_CH2_P
GS_CH2_N
0V_IO_EXT
A2.K5.X14
16
24V_CH1_EXT
GS_CH1_P
14
GS_CH1_N
13
15
0V_IO_EXT
10
24V_CH2_EXT
GS_CH2_P
12
GS_CH2_N
11
9
0V_IO_EXT