The digital inputs comply with the requirements of current sinking inputs type 1
for rated voltage 24 VDC according to IEC 61131-2:2017 clause 6.4.4.2.
For more connections other than those illustrated above, carefully assess the risk
before use and contact your local ABB for support.
Connector X15
Connection
Type
Article number
xx1800000555
Pin
1
3
5
7
9
11
13
15
17
The connector X15 allows for connecting automatic stop devices.
Automatic Stop is only operational in automatic mode. See
emergency stop on page
More information is also available in Application manual - Functional safety and
SafeMove.
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
Note
If external power supplies are used, they must have over-current protection. A
recommendation is to have separate fuses (0.5A) for each channel (Ch1, Ch2)
to increase diagnostic coverage on inputs.
Note
If separate power supplies are used for each channel (Ch1, Ch2) they must have
common ground.
17
15
13
18
16
14
Name
MON_PB1
MON_LAMP1
-
0V_IO_EXT
AS_CH2_N
ESOUT2_N
ESOUT1_N
AS_CH1_N
0V_IO_EXT
© Copyright 2022-2023 ABB. All rights reserved.
3 Installation and commissioning
3.5.9 Descriptions for connectors
Description
Connector for Safety IO signals
S2L 3.50 90F
Weidmüller
1728690000
11
9
7
5
12
10
8
6
Pin
2
4
6
8
10
12
14
16
18
21.
Continued
3
1
4
2
Name
24V_MON
24V_MON
-
24V_CH2_EXT
AS_CH2_P
ESOUT2_P
ESOUT1_P
AS_CH1_P
24V_CH1_EXT
Protective stop and
Continues on next page