3HAC081697-001 Revision: A
5.3.3 Replacing the HMI signal (FlexPendant) connector
Action
Insert the HMI signal connector into the
cover from inside the cabinet.
Secure it with the screws.
Reconnect any connectors disconnected
at removal.
Secure the cables on HMI signal connect-
or with new cable ties.
Tip
Use the same position as from removing
the HMI signal connector.
Refit the cover plate.
© Copyright 2022-2023 ABB. All rights reserved.
Note/Illustration
Screws: Torx, countersunk screw M4x10 (4
pcs)
Tightening torque: 1.7 Nm±10%.
xx2100000832
xx2300001847
Continues on next page
5 Repair
Continued
299