Conveyor tracking module (option)
For detail information on customer connections to conveyor tracking module, see
Application manual - Conveyor tracking, 3HAC066561-001.
xx2100002526
Customer cable layout
It is recommended to use multicore cable for the customer connection.
The cables connected by customer to the conveyor tracking module should go
through the cable grommet and fasten on the cabinet.
The cable layout is recommended as the following illustration.
24V terminal block (option)
This connector is internally connected with the optional power supply. It is a 24 V
power supply for the customer. The characteristics are shown in the following
table.
Parameter
Voltage
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
Note
The end user needs to install proper grommets according to the diameter of the
cables which need to go through the grommet.
Incorrect use of grommets will affect ingress protection, EMI/EMC and
temperature.
It is recommended to use icotek KT grommet.
Value
24 V DC
© Copyright 2022-2023 ABB. All rights reserved.