ABB OmniCore V400XT Product Manual page 261

Table of Contents

Advertisement

3
Removing the drive unit
1
2
Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
Action
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
45.
Action
Disconnect all connectors from the unit
to be replaced.
Remove the screws and pull the drive
unit out from the two guiding pins on the
mounting plate.
CAUTION
The weight of the drive unit is 11 kg.
Use protective gloves when lifting this
unit.
CAUTION
The cabling is sensitive to mechanical
damage. Handle it with care to avoid
damage to the cabling or the connector,
avoid any kind of tilt or skew.
© Copyright 2022-2023 ABB. All rights reserved.
5.2.13 Replacing the drive unit
Note/Illustration
Location of wrist strap button:
xx2300001842
Note/Illustration
Lengthened screwdriver
xx2100000338
Continues on next page
5 Repair
Continued
261

Advertisement

Table of Contents
loading

Table of Contents