2. Press the O button.
 Threading mode is switched on.
3. Loosen the screws (3).
4. Remove the throat plate (2).
5. Loosen the clamping screw (4).
6. Press the Zigzag
7. Set the position of the needle guide (5) accordingly.
8. Tighten the clamping screw (4).
9. Press the Zigzag
10. Check and, if necessary, correct the position of the needle guide.
11. Insert the throat plate (2).
12. Tighten the screws (3).

4.5 Bobbin capsule lifter

Fig. 20: Bobbin capsule lifter
(1) - Holder
The thread lever must pass the thread between the bobbin capsule (2) and
its holder (1). Unhindered passage of the thread requires that the bobbin
capsule be lifted at the right moment by the bobbin capsule lifter.
This will ensure the desired seam pattern with the lowest possible thread
tension.
Incorrect settings can have the following effects:
• Thread breakage
• Eyelets on the underside of the sewing material
• High noise level
42
Ensure that the positioning aids (1) are well fastened and cannot be
displaced.
Make sure that the positioning aids (1) are seated in the holes of the
throat plate.
button repeatedly.
button repeatedly.
(2) - Bobbin capsule
Service Instructions 806N-111-10/806N-121-10 - 00.0 - 09/2023