Check Output-Input - Dürkopp Adler 806N-111-10 Service Instructions Manual

Table of Contents

Advertisement

Service settings via software
To check the operation of the outfeed roller:
1. Press the Test advance roller
 The outfeed roller is raised/lowered.
2. Press the Test advance roller
 The outfeed roller is lowered/raised.

9.4.11 Check output-input

The overview of the outputs and inputs is used as a diagnostic tool which
can test and localize the functions and the parts of the machine, respec-
tively.
A press on the Output-Input
Fig. 135: Check output-input
Outputs
The outputs are listed in the upper portion. You can activate or deactivate
the outputs by tapping the buttons.
Buttons PWM1 and PWM2: Pulse-width-modulated outputs with magnets.
PWM1: Thread cutter. PWM2: Thread tension.
Service Instructions 806N-111-10/806N-121-10 - 00.0 - 09/2023
button.
button again.
button brings up the following screen:
159

Advertisement

Table of Contents
loading

This manual is also suitable for:

806n-121-10

Table of Contents