Machine head 121
Information
For cleaning purposes, the throat plate (4) can be removed after loosening
the screws (3) and (5), without causing any adjustment changes. The ad-
justing washers under the screws (1) and (2) will position the throat plate
again.
Proper setting
The needle should plunge into the center of the throat plate.
To set the throat plate:
1. Press the Lift/lower sewing head
button.
 The sewing head lowers.
2. Press the O button.
 Threading mode is switched on.
3. Loosen screws (1), (2), (3), and (5).
4. Align the throat plate (4).
5. Tighten screws (1), (2), (3), and (5).