5. Loosen the fastening screws of the control cam (4).
6. Turn the control cam on the lower shaft.
 When pressed down by hand, the ball bearing (6) must snap into the
 Select the axial position so that the control cam (4) and the roller (6)
7. Tighten the fastening screws of the control cam (4).

5.9.2 Setting the position of the stationary knife

Fig. 64: Setting the position of the stationary knife
(1) - Screw
(2) - Cutting pressure screws
Proper setting
The stationary knife (3), as viewed in arrow direction, must be in contact
with the screw (1) (see diagram).
To set the position of the stationary knife:
1. Turn back the cutting pressure screws (2).
2. Loosen the screw (1) from below.
3. Slide the knife (3) in arrow direction against the screws (1).
4. Tighten the screw (1) slightly from above.
5. Set the cutting pressure ( p. 95).
6. Tighten the screw (1) from below.
90
recess (5) of the control cam.
face each other.
WARNING
Risk of injury from sharp parts!
Cutting.
Only set the stationary knife with the machine
switched off.
(3) - Knife
Service Instructions 806N-111-10/806N-121-10 - 00.0 - 09/2023
Machine head 121