Dürkopp Adler 806N-111-10 Service Instructions Manual page 178

Table of Contents

Advertisement

Fig. 145: Setting the operating pressure
(1) - Pressure controller
(2) - Pressure gage transfer plate
(3) - Pressure gage vacuum
To set the operating pressure:
1. Turn the shut-off valve (6) to the horizontal position.
2. Pull the pressure controller operating pressure (7) up.
3. Turn the pressure controller until the pressure gage (5) indicates the
4. Push the pressure controller (6) back down.
176
(output y 134)
(output y 133)
proper setting:
• Increase pressure: turn clockwise
• Reduce pressure: turn counterclockwise
NOTICE
Property damage may occur!
Excessive pressure on the vacuum device may cause damage to the
machine.
Do not supply the vacuum device with compressed air of more than
3.5 bar.
(4) - Pressure controller
(5) - Pressure gage
(6) - Shut-off valve
(7) - Pressure controller operating pressure
Service Instructions 806N-111-10/806N-121-10 - 00.0 - 09/2023