Machine head 111
4.2.4 Setting the horizontal position of the throat plate
Fig. 10: Setting the horizontal position of the throat plate
(1) - Throat plate
(2) - Needle shaft
(3) - Screws
Proper setting
In X direction:
In the loop stroke position – or slightly further – the needle shaft (2) should
be distanced 0.3 mm from the right side of the throat plate (1).
In Y direction:
In this direction, the needle should plunge into the center of the throat
plate.
To set the horizontal position of the throat plate:
1. Press the Lift/lower sewing head
The sewing head lowers.
2. Press the O button.
Threading mode is switched on.
3. Loosen screws (3) and (5).
4. Set the position of the throat plate (4) accordingly.
5. Tighten screws (3) and (5).
Service Instructions 806N-111-10/806N-121-10 - 00.0 - 09/2023
WARNING
Risk of injury from moving parts!
Crushing.
The machine must be set to Threading mode.
①
②
③
④
(4) - Throat plate
(5) - Screws
⑤
button.
31